ARIES G

High-efficiency chiller for medium and large HVAC systems. Equipped with scroll compressors, high-performance heat exchangers and R454B refrigerant for sustainable energy savings.
Mode
Cooling
Cooling and heating
Heating
Cooling capacity
228 - 1303 kW
Refrigerant
R454B
Heat exchanger
Plate heat exchanger, shell-and-tube heat exchangers, heat recovery
Fans
Axial fan, EC axial fan
Compressors
Scroll
Non-ferrous application
Optional
Benefits
  • Ecological R454B refrigerant (GWP 466);
  • High SEPR HT values compliant with the requirements of the ERP directive (TIER 2, 01.01.2021 - base version) and SEPR MT (TIER 2, 02.07.2018 for the version with water outlet down to -10°C);
  • SHE and SSN acoustic configurations with reduced noise levels;
  • Wide application limits for commissioning and operation, even in unfavourable operating conditions;
  • Wide range of accessories and kits for easy installation; 
  • Easy access to all components;
  • Advanced electronic controller with integrated web server.
Technical specifications
  • Ecological R454B refrigerant;
  • 4 or 6 scroll compressors in 2 independent refrigeration circuits;
  • Crankcase heater and phase monitoring;
  • Shell-and-tube evaporator;
  • Victaulic connection kit for all models;
  • Electronic expansion valves;
  • Axial fans with die-cast aluminium blade profiles, fitted with a protective grille;
  • IP54 protection class for the control cabinet;
  • Microprocessor electronic controller with touchscreen for the user;
  • Factory refrigerant charge, oil charge and functional testing;
  • Thorough factory checks and tests;
  • Modbus RS485 interface for connection to monitoring systems;
  • Master/slave configuration to control two systems.
Versions
  • HE - base acoustic configuration;
  • SHE – Low-noise acoustic configuration;
  • SSN – Super low-noise acoustic configuration;
Accessories
  • Vibration damper kit;
  • Replicated remote user terminal as a kit;
  • xWEB300D EVO monitoring system;
  • Module control kit for xDRIVE controllers (master/slave from 3 to 8 systems).
Options
  • MWT configuration for low water outlet temperatures down to -10°C;
  • Equipment for low ambient temperatures down to -20°C;
  • Stainless steel tube-bundle evaporator;
  • Single or twin water pump (one on standby) with low or medium head;
  • Water storage tank;
  • Anti-freeze heater for evaporator, pump(s) and tank;
  • Compressor shut-off valves;
  • Soundproofing covers for the compressors (base equipment for EHC);
  • Soundproofed enclosure for tandem or trio compressors (base equipment for SSN);
  • High-efficiency EC fans (base equipment for SSN);
  • Full heat recovery;
  • Microchannel condenser coil;
  • Protective coating for the condenser coils, suitable for installation in aggressive environmental conditions;
  • Metal mesh filter to protect the condenser coils;
  • Soft starter for a 20% reduction in the system's starting current.